
Thermoelectric thermometer is based on:
A. Photoelectric Effect
B. Seebeck Effect
C. Compton Effect
D. Joule Effect
Answer
483k+ views
Hint: Thermoelectric thermometer is a special device which is used to measure low as well high temperature of an object or body. In thermoelectric thermometer different thermocouples are used for measuring the different range of temperature. Also here the concept of thermoelectricity is used.
Complete answer:
The concept we use in thermoelectric thermometer is thermoelectricity which occurs at junctions of dissimilar conductors or it may occur within the single conductor. In \[1821\] , Thomson Johann Seebeck observed a flow of electric current in the circuit made up of two conductors, when two junctions in the circuit were kept at different temperatures. The two junction is known as thermocouple and current flows through it is known as thermoelectric current. This is known as the Seebeck Effect.
According to this we can say that, when two different metals are joined together end to end. If one junction of thermocouple is kept at any fixed temperature which may be cold and another junction is kept in a hot region, then an e.m.f is developed between the junctions. The current which flows is called thermoelectric current. Thus we can say that the thermoelectric thermometer is based on the Seeback effect which helps in measuring temperature for different ranges of temperature.
Hence the correct option is B.
Note: The thermoelectric thermometer can be used for measuring different ranges of temperature. Copper couple is used for temperature range \[ - 200{{\text{ }}^ \circ }C\] to \[400{{\text{ }}^ \circ }C\]. The temperature of cold junction is kept at zero degree celsius and thus temperature of hot junction varies accordingly. The graph obtained between the temperature of the hot junction and e.m.f is known as the calibration curve.
Complete answer:
The concept we use in thermoelectric thermometer is thermoelectricity which occurs at junctions of dissimilar conductors or it may occur within the single conductor. In \[1821\] , Thomson Johann Seebeck observed a flow of electric current in the circuit made up of two conductors, when two junctions in the circuit were kept at different temperatures. The two junction is known as thermocouple and current flows through it is known as thermoelectric current. This is known as the Seebeck Effect.
According to this we can say that, when two different metals are joined together end to end. If one junction of thermocouple is kept at any fixed temperature which may be cold and another junction is kept in a hot region, then an e.m.f is developed between the junctions. The current which flows is called thermoelectric current. Thus we can say that the thermoelectric thermometer is based on the Seeback effect which helps in measuring temperature for different ranges of temperature.
Hence the correct option is B.
Note: The thermoelectric thermometer can be used for measuring different ranges of temperature. Copper couple is used for temperature range \[ - 200{{\text{ }}^ \circ }C\] to \[400{{\text{ }}^ \circ }C\]. The temperature of cold junction is kept at zero degree celsius and thus temperature of hot junction varies accordingly. The graph obtained between the temperature of the hot junction and e.m.f is known as the calibration curve.
Recently Updated Pages
Why are manures considered better than fertilizers class 11 biology CBSE

Find the coordinates of the midpoint of the line segment class 11 maths CBSE

Distinguish between static friction limiting friction class 11 physics CBSE

The Chairman of the constituent Assembly was A Jawaharlal class 11 social science CBSE

The first National Commission on Labour NCL submitted class 11 social science CBSE

Number of all subshell of n + l 7 is A 4 B 5 C 6 D class 11 chemistry CBSE

Trending doubts
What is meant by exothermic and endothermic reactions class 11 chemistry CBSE

10 examples of friction in our daily life

One Metric ton is equal to kg A 10000 B 1000 C 100 class 11 physics CBSE

1 Quintal is equal to a 110 kg b 10 kg c 100kg d 1000 class 11 physics CBSE

Difference Between Prokaryotic Cells and Eukaryotic Cells

What are Quantum numbers Explain the quantum number class 11 chemistry CBSE

