
The length of cylinder is $10.0\,cm$ and its radius is $4.00\,cm$ The percentage error in volume of cylinder will be:
A. $1.5\% $
B. $2\% $
C. $3.5\% $
D. $10.7\% $
Answer
495k+ views
Hint: In order to solve this question we need to understand the definition of cylinder which states that it is a closed shape enclosed by two parallel discs and curved rectangle. Now error is defined as the difference between actual value and calculated value. Percentage error of a quantity is the percentage of ratio of the calculated value to the original value. Volume represents the actual amount of space covered by an object.
Formula used:
Percentage error of any physical quantity depends upon other parameter as $Q = {a^x}{b^y}$
$\% Q = x(\% a) + y(\% b)$ which means the percentage error of quantity $Q$ is equal to $x$ times the percentage error in quantity $a$ and add with $y$ times percentage error in quantity $b$.
Volume of cylinder is $V = \pi {r^2}h$
Complete step by step answer:
According to the question, we have given that radius of cylinder is \[r = 4.00cm\] since, after decimal point the measurement accuracy is up to two decimals hence the minimum error in radius will be of $\Delta r = 0.01cm$ so,
Percentage error in radius will be written as
$\% r = \dfrac{{\Delta r}}{r} \times 100$
$\Rightarrow \% r = \dfrac{{0.01}}{4} \times 100$
$\Rightarrow \% r = 0.25 \to (i)$
Now, the height of cylinder is given $h = 10.0cm$ here, the measurement accuracy is up to one decimal point, so minimum error in height will be of $\Delta h = 0.1cm$ so,
percentage error in height will be written as
$\% h = \dfrac{{\Delta h}}{h} \times 100$
$\Rightarrow \% h = \dfrac{{0.1}}{{10}} \times 100$
$\Rightarrow \% h = 1 \to (ii)$
Now using formula of percentage error we have,
$V = \pi {r^2}h$ so using formula $\% Q = x(\% a) + y(\% b)$ we get,
$\% V = 2(\% r) + (\% h)$
On putting the value from equation $(i)and(ii)$ we get,
$\% V = 2(0.25) + (1)$
$\therefore \% V = 1.5$
So, the error in volume of cylinder is $1.5\% $
Hence, the correct option is A.
Note: It should be remembered that percent error is totally laboratory based instrumental error we can minimize the error by correcting technical issues but we can’t remove it because of Heisenberg uncertainty principle which states that conjugate pair like position momentum, energy time could not be measured simultaneously because Heisenberg Uncertainty Principle is inherent error in body but this is only viewed when we deal at microscopic level as at microscopic level matter waves do not interact with each other. Also mathematically we can calculate that error and add or subtract from the observed result so to get the correct answer.
Formula used:
Percentage error of any physical quantity depends upon other parameter as $Q = {a^x}{b^y}$
$\% Q = x(\% a) + y(\% b)$ which means the percentage error of quantity $Q$ is equal to $x$ times the percentage error in quantity $a$ and add with $y$ times percentage error in quantity $b$.
Volume of cylinder is $V = \pi {r^2}h$
Complete step by step answer:
According to the question, we have given that radius of cylinder is \[r = 4.00cm\] since, after decimal point the measurement accuracy is up to two decimals hence the minimum error in radius will be of $\Delta r = 0.01cm$ so,
Percentage error in radius will be written as
$\% r = \dfrac{{\Delta r}}{r} \times 100$
$\Rightarrow \% r = \dfrac{{0.01}}{4} \times 100$
$\Rightarrow \% r = 0.25 \to (i)$
Now, the height of cylinder is given $h = 10.0cm$ here, the measurement accuracy is up to one decimal point, so minimum error in height will be of $\Delta h = 0.1cm$ so,
percentage error in height will be written as
$\% h = \dfrac{{\Delta h}}{h} \times 100$
$\Rightarrow \% h = \dfrac{{0.1}}{{10}} \times 100$
$\Rightarrow \% h = 1 \to (ii)$
Now using formula of percentage error we have,
$V = \pi {r^2}h$ so using formula $\% Q = x(\% a) + y(\% b)$ we get,
$\% V = 2(\% r) + (\% h)$
On putting the value from equation $(i)and(ii)$ we get,
$\% V = 2(0.25) + (1)$
$\therefore \% V = 1.5$
So, the error in volume of cylinder is $1.5\% $
Hence, the correct option is A.
Note: It should be remembered that percent error is totally laboratory based instrumental error we can minimize the error by correcting technical issues but we can’t remove it because of Heisenberg uncertainty principle which states that conjugate pair like position momentum, energy time could not be measured simultaneously because Heisenberg Uncertainty Principle is inherent error in body but this is only viewed when we deal at microscopic level as at microscopic level matter waves do not interact with each other. Also mathematically we can calculate that error and add or subtract from the observed result so to get the correct answer.
Recently Updated Pages
Why are manures considered better than fertilizers class 11 biology CBSE

Find the coordinates of the midpoint of the line segment class 11 maths CBSE

Distinguish between static friction limiting friction class 11 physics CBSE

The Chairman of the constituent Assembly was A Jawaharlal class 11 social science CBSE

The first National Commission on Labour NCL submitted class 11 social science CBSE

Number of all subshell of n + l 7 is A 4 B 5 C 6 D class 11 chemistry CBSE

Trending doubts
What is meant by exothermic and endothermic reactions class 11 chemistry CBSE

10 examples of friction in our daily life

One Metric ton is equal to kg A 10000 B 1000 C 100 class 11 physics CBSE

1 Quintal is equal to a 110 kg b 10 kg c 100kg d 1000 class 11 physics CBSE

Difference Between Prokaryotic Cells and Eukaryotic Cells

What are Quantum numbers Explain the quantum number class 11 chemistry CBSE

